Tartalom
Képek
Kép feltöltése
DSS Images Other Images
Kapcsolódó cikkek
Rotational velocities of A-type stars in the northern hemisphere. II. Measurement of v sin i This work is the second part of the set of measurements of v sin i forA-type stars, begun by Royer et al. (\cite{Ror_02a}). Spectra of 249 B8to F2-type stars brighter than V=7 have been collected at Observatoirede Haute-Provence (OHP). Fourier transforms of several line profiles inthe range 4200-4600 Å are used to derive v sin i from thefrequency of the first zero. Statistical analysis of the sampleindicates that measurement error mainly depends on v sin i and thisrelative error of the rotational velocity is found to be about 5% onaverage. The systematic shift with respect to standard values fromSlettebak et al. (\cite{Slk_75}), previously found in the first paper,is here confirmed. Comparisons with data from the literature agree withour findings: v sin i values from Slettebak et al. are underestimatedand the relation between both scales follows a linear law ensuremath vsin inew = 1.03 v sin iold+7.7. Finally, thesedata are combined with those from the previous paper (Royer et al.\cite{Ror_02a}), together with the catalogue of Abt & Morrell(\cite{AbtMol95}). The resulting sample includes some 2150 stars withhomogenized rotational velocities. Based on observations made atObservatoire de Haute Provence (CNRS), France. Tables \ref{results} and\ref{merging} are only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.125.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/393/897
| A spectroscopic survey for lambda Bootis stars. II. The observational data lambda Bootis stars comprise only a small number of all A-type stars andare characterized as nonmagnetic, Population i, late B to early F-typedwarfs which show significant underabundances of metals whereas thelight elements (C, N, O and S) are almost normal abundant compared tothe Sun. In the second paper on a spectroscopic survey for lambda Bootisstars, we present the spectral classifications of all program starsobserved. These stars were selected on the basis of their Strömgrenuvbybeta colors as lambda Bootis candidates. In total, 708 objects insix open clusters, the Orion OB1 association and the Galactic field wereclassified. In addition, 9 serendipity non-candidates in the vicinity ofour program stars as well as 15 Guide Star Catalogue stars were observedresulting in a total of 732 classified stars. The 15 objects from theGuide Star Catalogue are part of a program for the classification ofapparent variable stars from the Fine Guidance Sensors of the HubbleSpace Telescope. A grid of 105 MK standard as well as ``pathological''stars guarantees a precise classification. A comparison of our spectralclassification with the extensive work of Abt & Morrell(\cite{Abt95}) shows no significant differences. The derived types are0.23 +/- 0.09 (rms error per measurement) subclasses later and 0.30 +/-0.08 luminosity classes more luminous than those of Abt & Morrell(\cite{Abt95}) based on a sample of 160 objects in common. The estimatederrors of the means are +/- 0.1 subclasses. The characteristics of oursample are discussed in respect to the distribution on the sky, apparentvisual magnitudes and Strömgren uvbybeta colors. Based onobservations from the Observatoire de Haute-Provence, OsservatorioAstronomico di Padova-Asiago, Observatório do Pico dosDias-LNA/CNPq/MCT, Chews Ridge Observatory (MIRA) and University ofToronto Southern Observatory (Las Campanas).
| Catalogue of Apparent Diameters and Absolute Radii of Stars (CADARS) - Third edition - Comments and statistics The Catalogue, available at the Centre de Données Stellaires deStrasbourg, consists of 13 573 records concerning the results obtainedfrom different methods for 7778 stars, reported in the literature. Thefollowing data are listed for each star: identifications, apparentmagnitude, spectral type, apparent diameter in arcsec, absolute radiusin solar units, method of determination, reference, remarks. Commentsand statistics obtained from CADARS are given. The Catalogue isavailable in electronic form at the CDS via anonymous ftp tocdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcar?J/A+A/367/521
| Determination of the temperatures of selected ISO flux calibration stars using the Infrared Flux Method Effective temperatures for 420 stars with spectral types between A0 andK3, and luminosity classes between II and V, selected for a fluxcalibration of the Infrared Space Observatory, ISO, have been determinedusing the Infrared Flux Method (IRFM). The determinations are based onnarrow and wide band photometric data obtained for this purpose, andtake into account previously published narrow-band measures oftemperature. Regression coefficients are given for relations between thedetermined temperatures and the photometric parameters (B2-V1), (b-y)and (B-V), corrected for interstellar extinction through use ofHipparcos parallaxes. A correction for the effect of metallicity on thedetermination of integrated flux is proposed. The importance of aknowledge of metallicity in the representation of derived temperaturesfor Class V, IV and III stars by empirical functions is discussed andformulae given. An estimate is given for the probable error of eachtemperature determination. Based on data from the ESA HipparcosAstrometry Satellite.
| Towards a fundamental calibration of stellar parameters of A, F, G, K dwarfs and giants I report on the implementation of the empirical surface brightnesstechnique using the near-infrared Johnson broadband { (V-K)} colour assuitable sampling observable aimed at providing accurate effectivetemperatures of 537 dwarfs and giants of A-F-G-K spectral-type selectedfor a flux calibration of the Infrared Space Observatory (ISO). Thesurface brightness-colour correlation is carefully calibrated using aset of high-precision angular diameters measured by moderninterferometry techniques. The stellar sizes predicted by thiscorrelation are then combined with the bolometric flux measurementsavailable for a subset of 327 ISO standard stars in order to determineone-dimensional { (T, V-K)} temperature scales of dwarfs and giants. Theresulting very tight relationships show an intrinsic scatter induced byobservational photometry and bolometric flux measurements well below thetarget accuracy of +/- 1 % required for temperature determinations ofthe ISO standards. Major improvements related to the actual directcalibration are the high-precision broadband { K} magnitudes obtainedfor this purpose and the use of Hipparcos parallaxes for dereddeningphotometric data. The temperature scale of F-G-K dwarfs shows thesmallest random errors closely consistent with those affecting theobservational photometry alone, indicating a negligible contributionfrom the component due to the bolometric flux measurements despite thewide range in metallicity for these stars. A more detailed analysisusing a subset of selected dwarfs with large metallicity gradientsstrongly supports the actual bolometric fluxes as being practicallyunaffected by the metallicity of field stars, in contrast with recentresults claiming somewhat significant effects. The temperature scale ofF-G-K giants is affected by random errors much larger than those ofdwarfs, indicating that most of the relevant component of the scattercomes from the bolometric flux measurements. Since the giants have smallmetallicities, only gravity effects become likely responsible for theincreased level of scatter. The empirical stellar temperatures withsmall model-dependent corrections are compared with the semiempiricaldata by the Infrared Flux Method (IRFM) using the large sample of 327comparison stars. One major achievement is that all empirical andsemiempirical temperature estimates of F-G-K giants and dwarfs are foundto be closely consistent between each other to within +/- 1 %. However,there is also evidence for somewhat significant differential effects.These include an average systematic shift of (2.33 +/- 0.13) % affectingthe A-type stars, the semiempirical estimates being too low by thisamount, and an additional component of scatter as significant as +/- 1 %affecting all the comparison stars. The systematic effect confirms theresults from other investigations and indicates that previousdiscrepancies in applying the IRFM to A-type stars are not yet removedby using new LTE line-blanketed model atmospheres along with the updatedabsolute flux calibration, whereas the additional random component isfound to disappear in a broadband version of the IRFM using an infraredreference flux derived from wide rather than narrow band photometricdata. Table 1 and 2 are only available in the electronic form of thispaper
| The Relation between Rotational Velocities and Spectral Peculiarities among A-Type Stars Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1995ApJS...99..135A&db_key=AST
| Vitesses radiales. Catalogue WEB: Wilson Evans Batten. Subtittle: Radial velocities: The Wilson-Evans-Batten catalogue. We give a common version of the two catalogues of Mean Radial Velocitiesby Wilson (1963) and Evans (1978) to which we have added the catalogueof spectroscopic binary systems (Batten et al. 1989). For each star,when possible, we give: 1) an acronym to enter SIMBAD (Set ofIdentifications Measurements and Bibliography for Astronomical Data) ofthe CDS (Centre de Donnees Astronomiques de Strasbourg). 2) the numberHIC of the HIPPARCOS catalogue (Turon 1992). 3) the CCDM number(Catalogue des Composantes des etoiles Doubles et Multiples) byDommanget & Nys (1994). For the cluster stars, a precise study hasbeen done, on the identificator numbers. Numerous remarks point out theproblems we have had to deal with.
| A survey for rapid variability among early main-sequence A stars A survey of nonpeculiar early (A0-A5) main-sequence A stars for rapid,low-amplitude variability is presented. The survey is also anindependent test of the main-sequence mass-loss theory proposed byWillson et al. (1986). All observations were gathered with theUniversity of Wisconsin Two-Star Photometer. Several period-searchingmethods are used to analyze time series of differential-photometricdata. This instrument coupled with a computerized high-speed datacollection system was used with small telescopes at Pine BluffObservatory and Table Mountain Observatory. Several period-searchmethods are used to analyze time series of differential-photometricdata. This instrument and data-reduction technique allow millimagnitudelight variations to be detected. The survey also discovered severallow-amplitude Delta Sct stars, all of which are in or blueward of therecognized instability strip.
| Atmospheric and temperature effects on differential photoelectric photometry The largest systematic errors in differential photoelectric photometryare the atmospheric effect and the temperature effect arising from thecolor difference between program star and comparison star. In the caseof AR Lac, the maximum difference in magnitude found by using individualextinction coefficients of comparison star and check star proved to beabout 0.05 mag. These results strongly suggest that the correction ofsecondary extinction effects in differential photoelectric photometry isvery important. The temperature coefficient of the whole photometer islarger than 0.0012 mag/C. This means that the temperature effect must beconsidered to avoid systematic errors when the temperature variation isabove 10 C.
| ICCD speckle observations of binary stars. I - A survey for duplicity among the bright stars A survey of a sample of 672 stars from the Yale Bright Star Catalog(Hoffleit, 1982) has been carried out using speckle interferometry onthe 3.6-cm Canada-France-Hawaii Telescope in order to establish thebinary star frequency within the sample. This effort was motivated bythe need for a more observationally determined basis for predicting thefrequency of failure of the Hubble Space Telescope (HST) fine-guidancesensors to achieve guide-star lock due to duplicity. This survey of 426dwarfs and 246 evolved stars yielded measurements of 52 newly discoveredbinaries and 60 previously known binary systems. It is shown that thefrequency of close visual binaries in the separation range 0.04-0.25arcsec is 11 percent, or nearly 3.5 times that previously known.
| Photometric study of the eclipsing binary system AR Lacertae AR Lacertae was observed photometrically during 16 nights in the periodOctober 1975 - January 1976. Three primary and three secondary minimawere observed. A mean period close to 1.983195 day was observed, in linewith previous data. Moments were calculated for the U, B and R lightcurves and are provided in terms of intensity as a function of the phaseangle. Roche constants were derived using Kopal's method and the Rocheradii were quantified for the primary and secondary components. The dataindicates the primary is near the main sequence, while the companion maybe a sub-giant. The primary has not filled its Roche lobe and may beabsorbing mass from the secondary.
| Interstellar reddening and distance of Nova Cygni 1978 Observations of Nova Cygni 1978 at 7699 A (a potassium line) are used toestimate the nova distance. The distance seems to be 3.3 plus or minus0.6 kpc with a corresponding absolute visual magnitude at maximum lightof approximately -7.5. The nova is classified as a fast galactic nova onthe basis of its absolute magnitude at maximum light and the rate ofdecline towards minimum light. The color excess deduced from theobservations is reported, application of the distance-reddening law tothe nova is explained, and a composite light curve is presented.
| Final catalogue of 229 photometric standards in UBV system near the selected areas 1-115 Not Available
| Spectrophotometry of RS Canum Venaticorum, AR Lacertae, and UX ARIETIS The wavelength dependences of the ultraviolet excesses of the RSCVn-type stars RS CVn, AR Lac, and UX Ari have been measuredspectrophotometrically with a wavelength resolution of 60 A. A number ofmechanisms are examined to account for the excess light from thesesystems, and it is concluded that free-free emission from hotcircumstellar gas provides the most satisfactory explanation.
| Absolute luminosity calibration of Stroemgren's 'intermediate group' A relation defining the luminosity index for Stroemgren's (1966)intermediate group (A0 to A3 stars) in terms of absolute magnitude iscalibrated using a method based on the principle of maximum likelihood.This relation is also calibrated for the case when the 'a' index iscorrected for reddening. For both relations, calculations are made ofthe magnitude dispersion, the mean velocity components and correspondingdispersion, and the precision of each parameter. The results are shownto be in fairly good agreement with Stroemgren's (1966) values, and arelation incorporating the corrected 'a' index is proposed formain-sequence stars. The absolute magnitudes obtained with a relation ofthe present type are compared with those derived from trigonometricparallaxes and with those obtained by Eggen (1972).
| The corrected magnitudes and colours of 278 stars near S.A. 1-139 in the UBV system Not Available
| Colors of bright stars. Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1954AJ.....59..228E&db_key=AST
|
Új cikk hozzáadása
Kapcsolódó hivatkozások
- - (nincs kapcsolódó hivatkozás) -
Új link hozzáadása
Besorolás csoportokba:
|
Pozíciós és asztrometriai adatok
Csillagkép: | Gyík |
Rektaszcenzió: | 22h06m12.40s |
Deklináció: | +45°14'55.0" |
Vizuális fényesség: | 6.19 |
Távolság: | 99.108 parszek |
RA sajátmozgás: | 22.8 |
Dec sajátmozgás: | -3.6 |
B-T magnitude: | 6.272 |
V-T magnitude: | 6.19 |
Katalógusok és elnevezések:
|